The Hydron Module Compact Vertical Packaged Series is built upon our heritage of superb craftsmanship with the highest quality materials and unmatched attention to detail. The Compact Vertical Packaged Series model combines many of the innovative features found in the Hydron Module product line with a smaller cabinet that is perfect for installations where space is limited.

Applications

Forced Air Heat Forced Air Cool Hot Water

Features

  • Single or two-stage scroll compressor
  • All-aluminum microchannel air coil
  • Sound and vibration absorbing compressor isolation pads
  • Digital controls with enhanced unit protection
  • Optional desuperheater (hot water generator)
  • Standard PSC or optional ECM blower motor
  • UL GREENGUARD certified foam cabinet insulation
  • Heavy gauge steel cabinet with attractive painted finish
  • Foam enclosed, enhanced surface coaxial heat exchanger
  • Meets ENERGY STAR requirements
  • Hydron Module Residential Warranty coverage

Performance Data

VS018

Cooling
Full Load BTU
21,400
EER
20.0
Part Load BTU
0
EER
0.0
Heating
Full Load BTU
16,300
COP
3.9
Part Load BTU
0
COP
0.0

VS024

Cooling
Full Load BTU
26,000
EER
19.7
Part Load BTU
0
EER
0.0
Heating
Full Load BTU
19,400
COP
4.0
Part Load BTU
0
COP
0.0

VS030

Cooling
Full Load BTU
30,600
EER
18.5
Part Load BTU
0
EER
0.0
Heating
Full Load BTU
23,900
COP
4.0
Part Load BTU
0
COP
0.0

VS036

Cooling
Full Load BTU
37,800
EER
18.0
Part Load BTU
0
EER
0.0
Heating
Full Load BTU
30,200
COP
3.9
Part Load BTU
0
COP
0.0

VS042

Cooling
Full Load BTU
43,600
EER
18.6
Part Load BTU
0
EER
0.0
Heating
Full Load BTU
32,000
COP
3.8
Part Load BTU
0
COP
0.0

VS048

Cooling
Full Load BTU
51,200
EER
17.6
Part Load BTU
0
EER
0.0
Heating
Full Load BTU
40,300
COP
3.6
Part Load BTU
0
COP
0.0

VS060

Cooling
Full Load BTU
60,000
EER
16.9
Part Load BTU
0
EER
0.0
Heating
Full Load BTU
46,900
COP
3.6
Part Load BTU
0
COP
0.0

VS072

Cooling
Full Load BTU
70,100
EER
15.1
Part Load BTU
0
EER
0.0
Heating
Full Load BTU
53,200
COP
3.3
Part Load BTU
0
COP
0.0

VT024

Cooling
Full Load BTU
25,800
EER
18.6
Part Load BTU
19,300
EER
24.2
Heating
Full Load BTU
19,400
COP
4.0
Part Load BTU
14,800
COP
3.8

VT036

Cooling
Full Load BTU
37,400
EER
17.7
Part Load BTU
28,500
EER
25.2
Heating
Full Load BTU
29,500
COP
3.9
Part Load BTU
22,900
COP
4.2

VT048

Cooling
Full Load BTU
51,300
EER
18.9
Part Load BTU
39,200
EER
27.2
Heating
Full Load BTU
38,300
COP
3.9
Part Load BTU
30,200
COP
4.3

VT060

Cooling
Full Load BTU
61,300
EER
17.6
Part Load BTU
46,900
EER
23.6
Heating
Full Load BTU
46,300
COP
3.8
Part Load BTU
37,000
COP
4.2

VT072

Cooling
Full Load BTU
71,000
EER
16.5
Part Load BTU
56,800
EER
22.3
Heating
Full Load BTU
51,900
COP
3.4
Part Load BTU
41,500
COP
3.9

Literature

Accessories

Non-programmable thermostat

Non programmable thermostat

Designed to take maximum advantage of the multi-stage functionality of the unit. This allows the unit to achieve maximum savings by only operating at the right range to match the current weather.

Programmable thermostat

Programmable thermostat

Keeps the home more comfortable by operating the unit on a set schedule and temperature range. This also saves on energy costs by setting the unit back while the home is unoccupied.

Flow centers - pressurized

Pressurized flow center

Circulates the fluid through the unit and loop field.

Flow centers - non-pressurized

Non pressure flow center

Circulates the fluid through the unit and the geothermal loop field. This type of system uses an expansion tank that can be topped off should the loop require it due to thermal expansion.

Unit air pad (plastic or foam)

Air pad

The unit air pad creates a buffer between the unit and the home. This buffer prevents any vibration from the unit to be transmitted into the home which improves the already quiet operation of the unit.

Electronic 24 volt air cleaner

24v electrostatic filter

This type of filter uses an electrically charged media to increase filtration performance. This improves indoor air quality by removing more particles from the airstream. This filter requires the occasional media replacement.

Electrostatic filter (washable)

Electrostatic filter

This type of filter is a permanent media filter that can be washed from time to time as needed. This eliminates the need to buy new filters.

Disposable pleated filter

Pleated filter

This type of filter uses a pleated media to remove dust and other particles from the air stream. It is important to check these filters regularly and replace them as needed.