Revolution Series Two-Stage Outdoor Split Geothermal System

Revolution rt
Revolution
Warranty badge

Let Hydron Module elevate your heating and cooling to a new standard. The Revolution Series outdoor split system can be added to your existing furnace or air conditioner, creating a highly efficient hybrid system. The outdoor split is also ideal for new construction as a stand-alone geothermal heat pump.

Applications

Forced Air Heat Forced Air Cool Hot Water

Features

  • Convenient side-mount flow center configuration
  • Digital controls
  • Easy access service panels
  • UV protected, powder coated steel cabinet
  • Copeland® UltraTech® two-stage scroll compressor
  • Built-in freeze protection
  • Flow center cover & aluminum pipe shield
  • Back-seated service valves with service ports
  • Optional factory installed desuperheater connection

Performance Data

RT024

Cooling
Full Load BTU
24,600
EER
15.9
Part Load BTU
19,600
EER
23.7
Heating
Full Load BTU
17,800
COP
3.4
Part Load BTU
14,700
COP
3.9

RT036

Cooling
Full Load BTU
36,000
EER
16.7
Part Load BTU
27,800
EER
25.3
Heating
Full Load BTU
27,200
COP
3.8
Part Load BTU
21,700
COP
4.2

RT048

Cooling
Full Load BTU
50,800
EER
18.0
Part Load BTU
39,000
EER
25.4
Heating
Full Load BTU
36,400
COP
3.9
Part Load BTU
29,800
COP
4.4

RT060

Cooling
Full Load BTU
61,500
EER
17.2
Part Load BTU
47,900
EER
24.1
Heating
Full Load BTU
45,600
COP
3.5
Part Load BTU
37,000
COP
4.1
  • Rated in accordance with ISO Standard 13256-1, which includes pump penalties.
  • Heating capacities based on 68.0°F DB, 59.0°F WB entering air temperature.
  • Cooling capacities based on 80.6°F DB, 66.2°F WB entering air temperature.
  • Entering water temperatures Full Load: 32°F heating / 77°F cooling.
  • Entering water temperatures Part Load: 41°F heating / 68°F cooling.

Literature

Accessories

Programmable thermostat

Programmable thermostat

Keeps the home more comfortable by operating the unit on a set schedule and temperature range. This also saves on energy costs by setting the unit back while the home is unoccupied.

Non-programmable thermostat

Non programmable thermostat

Designed to take maximum advantage of the multi-stage functionality of the unit. This allows the unit to achieve maximum savings by only operating at the right range to match the current weather.

Auxiliary internal electric heater

Internal heater

Adds that little bit of extra heat on those few coldest days. Also helps to balance the system size by balancing out those few extreme days. With a standard stab-in design, you don't have to drop the blower to install.

Auxiliary external electric heater

External heater

Adds that little bit of extra heat on those few coldest days. Also helps to balance the system size by balancing out those few extreme days. These heaters are installed in the supply air duct outside of the unit. Mostly used on horizontal style equipment.

Flow centers - pressurized

Pressurized flow center

Circulates the fluid through the unit and the geothermal loop field. These types form a completely closed system.

Flow center - non-pressurized

Non pressure flow center

Circulates the fluid through the unit and the geothermal loop field. This type of system uses an expansion tank that can be topped off should the loop require it due to thermal expansion.

EWC zone control

Zone control

These highly sophisticated controls work with dampers in the ductwork to create multiple zones throughout the house. You can utilize one unit, but have different temperatures in each zone. The control panel controls both the unit, and the zone dampers.

Unit air pad (plastic or foam)

Air pad

The unit air pad creates a buffer between the unit and the home. This buffer prevents any vibration from the unit to be transmitted into the home which improves the already quiet operation of the unit.

Electrostatic filter (washable)

Electrostatic filter

This type of filter is a permanent media filter that can be washed from time to time as needed. This eliminates the need to buy new filters.

Electronic 24 volt air cleaner

24v electrostatic filter

This type of filter uses an electrically charged media to increase filtration performance. This improves indoor air quality by removing more particles from the airstream. This filter requires the occasional media replacement.

Disposable pleated filter

Pleated filter

This type of filter uses a pleated media to remove dust and other particles from the air stream. It is important to check these filters regularly and replace them as needed.

Consumer purchase plans

Purchase plan

With a wide variety of payment options and terms, our consumer payment plans make installing a geothermal system easier and more cost effective. By deferring your initial payments out, you can start enjoying your new system earlier and take time to obtain many of the various rebates and tax credits offered.